ACCON-MPI-Profibus-Modem

ACCON-MPI-Profibus-Modem

$650.00

The ACCON-MPI/PROFIBUS-Modem is the high tech remote maintenance and programming adaptor fort he S7 controller.

Free worldwide shipping on all orders over $50

  • 30 days easy returns
  • Order yours before 2.30pm for same day dispatch
Guaranteed Safe Checkout

Product Description

Description

The number one among the remote maintenance adaptors

The ACCON-MPI/PROFIBUS-Modem is the high tech remote maintenance and programming adaptor fort he S7 controller.
The ACCON-MPI/PROFIBUS-Modem is a TS adaptor with integrated modem. Due to its compact mounting form, the device fits in each control box.
As all-rounder, the ACCON-MPI/PROFIBUS-Modem can be connected to the S7 controller via MPI and PROFIBUS. A bushing to connect a further device, e.g. control panel, exists at the bus plug. The bus plug contains an electronic system which separates the connection cable of the ACCON-MPI/PROFIBUS-Modem and the bus (MPI or PROFIBUS) so that the connection cable will not be a spur line.

Perfect fields of application

  • As programming adaptor to create and change the PLC program
  • As communication adaptor for visualizations
  • As communication adaptor for data access to the PLC
  • As remote maintenance unit for S7 PLCs and SIMATIC panels

Varied ranges of application

Remote switching S7 PLCs with STEP 7 via modem
Translating the program into the S7 PLC with STEP 7 via modem

Convincing and varied

The ACCON-MPI/PROFIBUS-Modem autonomously detects the current bus profile of the PLC.
The communication of the ACCON-MPI/PROFIBUS-Modem to the PC is effected via USB or RS-232. It can be fed with 24 VDC externally.

Technical highlights

  • Compact mounting form
  • Fast bringing into service
  • Modem and TS adaptor in one device
  • Mounting on top-hat rail
  • Automatic bus profile detection
  • Full PROFIBUS speed up to 12 Mbps
  • Active connection cable, therefore no spur lines

You have the choice

Three models of the ACCON-MPI/PROFIBUS-Modem can be supplied which differ in the integrated modem type: You can choose between the model with integrated analogue modem, the model with integrated ISDN adaptor and the model with integrated Quadband GSM modem.
For the ACCON-MPI/PROFIBUS-Modem GSM you need a GSM antenna which has to be bought separately. Furthermore, you need a SIM card with data activation (CSD – Circuit Switched Data): Typically, it has a separate telephone number for incoming data connections. For further information, please contact your wireless network operator.

Technical data

ACCON-MPI/PROFIBUS-Modem 56k ACCON-MPI/PROFIBUS-Modem ISDN ACCON-MPI/PROFIBUS-Modem GSM
Telephone connection Connection cable for TAE socket and RJ11 socket (western bushing) (each 3 m) ISDN-Connection cable (3 m) FME bushing for GSM antenna (antenna is not included in delivery)
Supported ISDN protocols DSS1 (Euro-ISDN)
Supported GSM network frequencies 850 MHz, 900 MHz, 1800 MHz, 1900 MHz
Connection to the PC for parametrization RS-232 with 9-pin SUB-D bushing, via included cable;
USB bushing type Mini-B, via included cable
RS-232 with 9-pin SUB-D bushing, via included cable;
USB bushing type Mini-B, via included cable
RS-232 with 9-pin SUB-D bushing, via included cable;
USB bushing type Mini-B, via included cable
Connection to the PLC 9-pin SUB-D plug with PG bushing, stationary mounted cable (ca. 1.2 m), active (no spur line) 9-pin SUB-D plug with PG bushing, stationary mounted cable (ca. 1.2 m), active (no spur line) 9-pin SUB-D plug with PG bushing, stationary mounted cable (ca. 1.2 m), active (no spur line)
Supported transmission rates of the bus connection to the PLC 9.6 KBit/s to 12 MBit/s with automatic detection 9.6 KBit/s to 12 MBit/s with automatic detection 9.6 KBit/s to 12 MBit/s with automatic detection
Supported bus profiles MPI and PROFIBUS (DP, Standard, universal (DP/FMS), user-defined) both fixed and with automatic detection of the bus parameters MPI and PROFIBUS (DP, Standard, universal (DP/FMS), user-defined) both fixed and with automatic detection of the bus parameters MPI and PROFIBUS (DP, Standard, universal (DP/FMS), user-defined) both fixed and with automatic detection of the bus parameters
Supported transfer rate RS-232 9.6 KBit/s to 115.2 KBit/s 9.6 KBit/s to 115.2 KBit/s 9.6 KBit/s to 115.2 KBit/s
Supported transfer rate USB 12 MBit/s (USB 1.1) 12 MBit/s (USB 1.1) 12 MBit/s (USB 1.1)
Supported PLCs S7-300, S7-400 (S7 compatible PLC, e.g. Vipa, Saia, Berthel) S7-300, S7-400 (S7 compatible PLC, e.g. Vipa, Saia, Berthel) S7-300, S7-400 (S7 compatible PLC, e.g. Vipa, Saia, Berthel)
Max. number of connections to MPI, PROFIBUS 8 8 8
Weight in kg Ca. 0.24 Ca. 0.24 Ca. 0.24
Dimensions (W x H x D) in mm 67 x 135 x 30 67 x 135 x 30 67 x 135 x 30
Protection type IP 20 IP 20 IP 20
Supply voltage 24 VDC ± 25 % 24 VDC ± 25 % 24 VDC ± 25 %
External voltage feed possible Yes Yes Yes
Power consumption Ca. 140 mA Ca. 140 mA Ca. 140 mA
Operating temperature 0 °C to 60 °C 0 °C to 60 °C 0 °C to 60 °C
Storage/transporting temperature -20 °C to 60 °C -20 °C to 60 °C -20 °C to 60 °C
Allowed relative humidity Operating 5 % to 85 % at 30 °C (no bedewing), storage 5 % to 93 % at 40 °C (no bedewing) Operating 5 % to 85 % at 30 °C (no bedewing), storage 5 % to 93 % at 40 °C (no bedewing) Operating 5 % to 85 % at 30 °C (no bedewing), storage 5 % to 93 % at 40 °C (no bedewing)
Galvanically isolated Yes Yes Yes

[woocommerce_product_documents]

Reviews

There are no reviews yet.

Be the first to review “ACCON-MPI-Profibus-Modem”

Your email address will not be published. Required fields are marked *